Shunts with rated voltage drop 60-100-150 mV for DC instruments

For more informations download datasheet.

 

Scheda tecnica prodotto

CHARACTERISTIC

  • Accuracy class 0.5
  • Manufactured according to DIN Standards 43703 and IEC Recommendations
  • Soldering by silver at 600 °C
  • Supplied with screw bolt for current and voltage connections
  • Reconnections voltage: 2 screw M5 X 8 with 4 washers
  • Two calibrated leads (on request): 1.5 m – 2.5 mm² – 0.02 Ω
  • Overloads:
    1.2 In continuous
    10 In for 5 seconds up to 250 A
    5 In for 5 seconds from 251 up to 2000 A
    2 In for 5 seconds from 2001 up to 15000 A

Contattaci

[si-contact-form form="1"]